Wednesday, January 9, 2008

Disabling RTE (Real-Time Events) in EnterpriseOne

This is my updated instruction on disabling RTE (Real-Time Events) in EnterpriseOne 8.12 as the instruction on the knowledge garden is targeted only for 8.11 SP1:

1. Determine the RTE event errors found in call object kernel log inside SAW Enterprise. Look for "Failed to get event definition for event XXXXXX. Please check is event definition correct?"


2. From the solutions explorer, open P90701A (Event Definition Workbench).

3. Click on Find and see if the event XXXXXX is already present, if not add the event. Use the "JD Edwards EnterpriseOne Application Real-Time Events 8.12 Implementation Guide" in adding the necessary fields.

4. From the Form Exit bar (Click on Preferences >> Exit Bar menu if hidden) click on the "Event Activation".

5. Click on Find and see if the event XXXXXX is already present, if not add the event. On the environment use the J prefix environment e.g. JPD812.

6. After adding, click on Find again to refresh the grid. On the Event Status make sure it's "NA", if not Use the Row Exit bar to change status.

7. Restart the JDE Service to effect the changes.

Notes:
The documentation on "JD Edwards EnterpriseOne Application Real-Time Events 8.12 Implementation Guide" (April 2006) is not written correctly.

Event Entry Application fields:
Event Type - refers to Event Name in the guide.
Event Category - refers to Event Type in the guide.
Event Aggregate - refers to Event Category in the guide.